Product Description
Siemens 5WG1545-1DB31, N 545D31
-
For control of drives with a DC motor for DC 24 V
-
Two relays per output for polarity switching of the output voltage
-
Rated contact operating voltage DC 24 V
-
Rated contact current: 6 A
-
Electronics for detection of the actuation of an electromechanical and electronic limit switches
-
Automatic travel time determination via current detection
-
Per actuator channel direct operation function on the device for driving solar protection up/down, stop command and slat adjustment
-
Two status LEDs per actuator channel to indicate the direction of travel and an override
-
Button on the device front for deactivation of the direct mode operation and LED to indicate activation direct mode operation
-
Maintenance-free terminals for connection and through-wiring of untreated single-core, stranded or multi-core conductors, 0.5 ... 2.5 mm²
-
Two terminals per actuator channel for motor connection (up, down)
-
Two terminals on the device to connect the DC 24 V (+/-) to supply the load circuits
-
Bus-powered electronics
-
Housing: plastic, color RAL 7035 (light grey), N-system
-
DIN rail mounted device for mounting on rail TH35 according to DIN EN 60715
-
Type of protection: IP 20
Additional functionalities GAMMA
-
Selectable operation mode blinds, shutter/awning, ventilation flap
-
Per actuator channel motion commands for moving and stopping the solar protection or for adjustment of blind slats
-
Per actuator channel direct movement to a position of the sunblind and the blind slats
-
Per actuator channel central movement of the solar protection in manual mode and automatic mode and delay time for Up / Down
-
Distinction between automatic and manual mode (position of the sunblind and blind slats) and adjustable behaviour in sunshine
-
Programming and recalling preset positions 1-4 and 8-bit scene control
-
Adjustable behaviour in case of override (wind, rain, frost, lock, forced position, forced control, range limitation)
-
Adjustable reverse pause time and delay times of the drives
-
Per actuator channel configurable state on bus voltage failure and start value on bus voltage recovery
-
Adjustable transmission of status objects (direct operation, automatic operation, curtain and slat position, travel, calibration travel time to end positions, overriding) on request, cyclically and/or upon change
-
Adjustable transmission time of the status objects after bus voltage recovery and transmission delay between the status objects
-
Surveillance of device function